Hurricane Impact Systems
Sto Hurricane Impact (HI) Systems provide a full range of exterior cladding options to protect against hurricane and tropical storm winds, water intrusion, and wind-borne debris which is a leading cause of building envelope failure. All of Sto’s Hurricane Systems meet the stringent Miami-Dade County, Florida NOA criteria for impact resistance, air and water infiltration, and wind load resistance.
Resource Links
- Competitively priced with other building envelope systems.
- Fire-resistance rated wall assemblies.
- Lightweight and easy to install.
- Backed by Sto warranties.
| System | Application Type | Large Missle | Small Missle | NOA Description | NOA Number | Design Pressure | Steel Gauge | View System | Compare |
|---|---|---|---|---|---|---|---|---|---|
| StoVentec Fiber Cement | Field Applied | ❌ | ❌ | No Description | No NOA | +/-44 to +/-95 | No Gauge | View | |
| Sto Ventec Glass Ply | Field Applied | ✅ | ✅ | StoVentec Glass Composite Rainscreen Wall System | 22-0606.05 | +/-75 to +/-100 | 18 gauge | View | |
| Sto Ventec Render MVF - LM/SM | Field Applied | ✅ | ✅ | StoVentec Render and StoVentec for Masonry Veneer Facades Composite Rainscreen Wall Systems | 22-1103.02 | +/-55 | 18 gauge | View | |
| Sto Ventec Render | Field Applied | ✅ | ✅ | StoVentec Render and StoVentec for Masonry Veneer Facades Composite Rainscreen Wall Systems | 22-1103.02 | +/-55 | 18 gauge | View | |
| Sto Powerwall GMG - Structa Wire | Field Applied | ✅ | ✅ | Sto Powerwall HI Wall Panel System with Structa Wire Twin Trac 2.5 and Stucco over 5/8" eXP Gypsum Sheathing | 23-0518.03 | +/-100 | 18 gauge | View | |
| Sto Powerwall Drainscreen GMG | Field Applied | ✅ | ✅ | Sto Powerwall HI Wall Panel System with Wire Lath & Stucco & optional DrainScreen over 5/8" eXP Gypsum Sheathing | 23-1010.13 | +/-100 | 18 gauge | View | |
| StoPowerwall GMG | Field Applied | ✅ | ✅ | Sto Powerwall HVHZ Wall Panel System with Wire Lath and Stucco over 5/8" eXP Gypsum Sheathing | 22-1215.05 | +/-100 | 18 gauge | View | |
| StoTherm ci CMU | Field Applied | ✅ | ❌ | Sto Therm ci LM 180 CMU EIF System | 21-0708.13 | -180 | N/A | View | |
| StoTherm ci Ply | Field Applied, Prefab (Sto Panel) | ✅ | ❌ | StoTherm ci - PLY SF/WF EIFS Systems | 23-0328.03 | +/-100 to +/-125 | 18 gauge | View | |
| StoTherm ci StoCast GMG-SM | Field Applied, Prefab (Sto Panel) | ❌ | ✅ | StoTherm ci with StoCast Wood EIFS System | 23-0707.04 | +/-112 | 18 gauge | View | |
| StoTherm ci StoCast GMG-LM | Field Applied, Prefab (Sto Panel) | ✅ | ❌ | StoTherm ci with StoCast Wood EIFS System | 23-0707.03 | +/-105 | 18 gauge | View | |
| StoTherm ci MVES GMG - SM | Field Applied, Prefab (Sto Panel) | ❌ | ✅ | StoTherm ci MVES Masonry Veneer-SM | 22-1118.02 | +/-112 | 18 gauge | View | |
| StoTherm ci MVES GMG - LM | Field Applied, Prefab (Sto Panel) | ✅ | ❌ | StoTherm ci MVES Masonry Veneer-LM | 22-1118.01 | +/-103 | 18 gauge | View | |
| StoTherm ci GMG – LM/SM | Field Applied, Prefab (Sto Panel) | ✅ | ✅ | StoTherm ci LM/SM 1177-18ga. EIFS System | 21-0722.07 | +/-120 to +/-150 | 18 gauge | View | |
| StoTherm ci GMG – SM | Field Applied, Prefab (Sto Panel) | ❌ | ✅ | StoTherm ci 1177-SM EIFS System | 22-1212.03 | +/-120 to +/-150 | 16 gauge | View | |
| StoTherm ci GMG - LM | Field Applied, Prefab (Sto Panel) | ✅ | ❌ | 22-1212.02 | +/- 150 Nat Gyp +/-150 USG | 16 gauge | View |